Multi poses calibration

This article goes through the main steps in the multi poses calibration process:

Fixing the calibration plate

Fixed camera

If the camera is fixed to a static structure, the calibration plate must be mounted on the robot flange. For multi poses calibration it does not matter how the plate is mounted, as long as it’s fixed rigidly to the flange.

Refer to Installing the Pickit calibration plate for the standard way to mount the plate.

../../_images/calibration_multi_pose_fixed_camera_plate_attachment.png

Robot mounted camera

If the camera is mounted on the robot flange, place the calibration plate on a surface, at a comfortable distance from the robot. The location of the plate should correspond to the picking area.

../../_images/calibration_multi_pose_plate_in_view.png

Building the robot program

In the robot interface, open the multi poses calibration template program, or create one your own. This program repeats five times the following sequence: move to a waypoint and request Pickit to find the calibration plate. Each of the five waypoints should be defined such that:

  • The calibration plate is shown to the robot approximately in the center if the Pickit 2D view.

  • The calibration plate is presented to the camera at different angles around the X, Y and Z axes of the plate. The angles should be large enough (for instance 30 degrees), while still making sure that the plate is clearly visible in the Pickit 2D viewer.

../../_images/Calibration-plate-visible-viewer.png ../../_images/Calibration-plate-visible.png

Program for fixed camera

Move the robot such that the plate is in the middle of the field of view of the camera. Move the flange to five different angle combinations around the X, Y and Z axes.

../../_images/calibration_multi_pose_fixed_camera.png

Program for robot mounted camera

Teach the five waypoints such that the plate always appears approximately in the center of the image, but tilted in different directions.

../../_images/calibration_multi_pose_camera_on_robot.png

Calibrating

  1. Click on the Calibration button, located on top of the Pickit web interface.

  2. Choose the camera mount: whether the camera is fixed to a stationary place or robot mounted.

  3. Select the correct robot type: 6 DOF or 4 DOF, depending on the number of degrees-of-freedom of your robot. If your robot has only 4 degrees-of-freedom, fill in the field Flange Z-axis with the distance between the robot base and the camera (if the camera is fixed) or the distance between the robot flange and the camera (if the camera is mounted). Notice that, for a mounted camera, if the camera is mounted at a higher location than the robot flange, this value should be negative.

  4. Choose the multi poses robot camera calibration method.

  5. Follow the indicated steps, and run the robot program when instructed. The Pickit web interface shows the progress of the calibration process.

../../_images/Calibration-progress-multi-poses.png

Important

After finishing robot camera calibration, don’t forget to check the calibration result. Go to Checking robot camera calibration to know how. If your robot has 4 degrees-of-freedom, and you are not sure whether the distance between robot base (or flange) and camera is correct, you can use the 3D viewer to check whether the distance between the frames corresponds to reality.

Warning

If after calibration the Pickit camera has been relocated or rotated relatively to the robot base, a new robot camera calibration is required before picking, even if the motion was small.